The exhaust of Diesel generator is not only harmful but also high temperature, so the design of exhaust system should be paid special attention

 

If the back pressure of the exhaust system on the engine exceeds the specified value, the performance of the engine will be affected and the maintenance interval will be shortened

 

The shorter the exhaust system, the smaller the resistance (and back pressure), and the bending parts within the system have a significant impact on the resistance. The maximum allowable resistance of the exhaust system is

 

R=450 mmH20: All models except SR.6D

 

600 mmH20: SR

 

816 mmH20: 6D

 

The resistance is measured at the outlet of the turbocharger

 

The recommended material for the exhaust pipe is carbon steel pipe (non galvanized)

 

1.1 Calculation of exhaust resistance and determination of exhaust pipe diameter

 

The exhaust resistance is affected by exhaust pipelines and silencers, etc

 

The exhaust resistance of the pipeline is obtained from the following equation

 

Pipe Diameter 

Insisde Diameter

External Diameter

A

B

150

200

250

300

350

400

450

500

6

8

10

12

14

16

18

20

155.2

204.7

254.2

304.7

339.8

390.6

441.4

492.2

165.2

216.3

267.4

318.5

355.6

406.4

457.2

508.0

 



mag-subscribe sa aming newsletter
mag-sign up para sa aming buwanang promosyon at lumabas ng pinakabagong balita ng produkto!

Mag-click dito upang mag-iwan ng mensahe

mag-iwan ng mensahe
kung interesado ka sa aming mga produkto at nais mong malaman ang higit pang mga detalye, mangyaring mag-iwan ng mensahe dito, tutugon kami sa iyo sa lalong madaling panahon.

Bahay

Mga produkto

tungkol sa

Makipag-ugnay sa